Thermocouple for a gas boiler: detailed instructions on the design and principle of operation, checking the serviceability of the thermoelectric sensor with a multimeter, restoration and replacement

All boilers, regardless of their type of operation, need components that will control the operation of the unit and ensure that it does not overheat. Such an element is a thermocouple for a gas boiler. It has a fairly simple structure, and its operation is based on the laws of physics. A similar element is very often used in various devices to control the temperature of the working environment, as well as to convert thermal energy into electric current.

The thermocouple design of a gas boiler is both simple and reliable. It consists of two conductors made of different materials that contact each other at several points. Sometimes, to be sure, they are connected using compensation wires. Such a device does not require external stimulation, which allows it to be used for any purpose. The disadvantage of the device is the large measurement error, which can reach one degree Celsius. This is a huge indicator for devices of this type.

The design and principle of operation of a thermocouple

Indeed, not every material can be constantly in the open flame zone.
The thermoelement is made of metal, or rather, of several metals, so it is not afraid of high temperatures. When operating a gas boiler installation, there is no way to do without it; failure of the thermocouple means a complete shutdown of the unit and immediate repairs. The thing is that the thermoelement works in conjunction with an electromagnetic shut-off valve that closes the entrance to the fuel path. As soon as this part fails, the valve will close, the fuel supply will stop and the burner device will go out. To better understand the principle of operation of a gas boiler thermocouple, it is worth considering the diagram presented in the figure.

Thermocouple circuit

This principle is based on the following physical phenomenon: if you reliably connect 2 dissimilar metals together, and then heat the junction, then a potential difference, that is, voltage, will appear at the cold ends of this junction. And when a measuring device is connected to them, the circuit will close and a direct electric current will arise. The voltage will be very small, but this is quite enough for induction to occur in the sensitive coil of the solenoid valve and it to open, allowing fuel to pass to the igniter.

For reference. Some modern solenoid valves are so sensitive that they remain open until the input voltage drops below 20 mV. The thermocouple in normal operating mode produces a voltage of about 40-50 mV.

Accordingly, the device of a gas boiler thermocouple is based on the described phenomenon, called the Seebeck effect. Two parts made of different metals are firmly connected to each other at one or more points, and the quality of the connection plays a big role. It affects the operating parameters of the element and the durability of its operation. The connection point will be the very working part placed in the open fire zone.

Since many different pairs of metals are used for the manufacture of thermoelements, without going into details, we note that the thermocouple for a gas boiler uses a chromel - aluminum pair. Conductors enclosed in a protective sheath are welded to the cold ends of these metals. The second end of the conductors is inserted into the corresponding socket of the unit automation and secured with a clamping nut.

In the process of igniting the igniter and burner of a gas boiler to supply fuel, we open the solenoid valve manually by pressing its rod. The gas enters the igniter and is ignited, and the thermocouple is located nearby and is heated by its flame. After 10-30 seconds, the button can be released, since the thermoelement has already begun to generate voltage that keeps the valve stem open.

What is it for?

The thermocouple is used to convert thermal energy into electric current for electromagnetic coils in gas boilers and serves as the main element of gas control protection.
It is made of several types of metal that are resistant to maximum temperatures inside the combustion chamber. The thermocouple works in conjunction with an automatic gas shut-off valve, which shuts off the gas supply to the fuel path.

It is important to know: the protective circuit of gas boilers is designed in such a way that if the thermoelectric element fails or the flame suddenly disappears, the shut-off valves are automatically activated and the gas supply is stopped.

How does a flame sensor work in a gas boiler?

A flame ionization sensor is a device that is designed to ensure the safe operation of gas boiler equipment. The device monitors the presence of fire, and if it detects a lack of flame, it automatically turns off the boiler. The operating principle of the gas boiler flame sensor provides the following:

  • the functionality is based on the formation of ions and electrons when the flame is ignited. The formation of an ionic current causes the process of attracting ions to the ionization electrode. The device is connected to a combustion control sensor;
  • If, when checking with a combustion control sensor, the formation of a sufficient level of ions is detected, this means that the boiler is operating normally. If the ion level decreases, the sensor blocks the operation of the boiler equipment.

The key reasons for the operation of the ionization sensor include contamination of the valve and incorrect gas-air level ratio. This also happens when a large amount of dust settles on the ignition device.

Temperature sensors. Classification

There are several main types of thermocouples. They are distinguished by the material they are made of. The main materials used for temperature sensors are metals - noble and base. It was their combination that became the basis of the classification. Here are the most common types of thermoelectric elements

:

  • Type K: Chromel and alumel. Temperature range (long term): from 0°C to +1100°C;
  • Type J: Iron and constantan. Temperature range (long term): from 0°C to +700°C;
  • Type N: Nicrosil and nisil. Temperature range (long term): from 0°C to +1100°C;
  • Type R: Platinum-rhodium (13% Rh) and platinum. Temperature range (long term): from 0°C to +1600°C;
  • Type S: Platinum rhodium (10% Rh) and platinum. Temperature range (long term): from 0°C to +1600°C;
  • Type B: Platinorhodium (30% Rh) and platinumrhodium (6% Rh). Temperature range (long term): from +200°С to +1700°С;
  • Type T: Copper and constantan. Temperature range (long term): from -185°C to +300°C;
  • Type E: Chromel and constantan. Temperature range (long term): from -50°С to +800°С;


Types of thermoelectric elements
Of course, each type of thermoelectric element is used for different purposes. Expensive thermocouples are used in science and industry, while simpler and cheaper ones are ideal for domestic use - in gas boilers or stoves.

Differences from temperature sensor

In addition to the thermocouple, a thermal cylinder is connected to the automatic fuel valve of the boiler, which is responsible for turning off the main burner when the set coolant temperature is reached. Externally, the element flasks and copper connecting tubes are somewhat similar. An uninformed homeowner can easily confuse these sensors.

Let us list the main differences between a temperature meter and a thermocouple:

  • sensor design - a cylindrical bellows made in the form of a copper flask with a sealed end;
  • the thermal cylinder is connected to the gas automatics with a thinner capillary tube than the electricity-generating sensor;
  • the heat-sensitive flask itself is installed inside the immersion sleeve or hidden under the casing near the water jacket, and is not attached near the igniter;
  • The temperature meter does not detach from the automation at all or the size of the fastening nut differs.

Note. The thermal balloon operates on a different principle: when heated, a special liquid expands inside the flask. The pressure through the capillary is transferred to the automatic valve, which turns off the main burner. The igniter flame does not go out.

Advantages and disadvantages

Due to the fact that making a thermocouple is quite simple and inexpensive, it has become an indispensable element of automation and control in gas-using equipment. In addition, there are other advantages of these products:

  • Acting as a flame control sensor, the thermoelectric element can also work as a temperature sensor.
  • The absence of moving parts, complex components and expensive materials makes the product inexpensive and durable.
  • Wide range of measured temperatures.
  • Sufficient measurement accuracy to allow the use of this device in heating equipment.
  • The simplicity with which the thermocouple is installed or replaced in a gas boiler.

Among the disadvantages of thermoelectric sensors, it can be noted that the increase in the potential difference does not occur in proportion to the increase in temperature, that is, the dependence is nonlinear. In addition, the voltage increase has a limit and it is small; in the thermocouple of gas boilers its value reaches 50 mV. Such properties of the product do not create problems when interacting with a cut-off device, but when measuring temperature, such a weak and nonlinear signal requires amplification and calibration.

The simplicity and reliability of the thermoelectric sensor design also have a negative side. When this element fails, which sometimes happens due to poor quality of the junction, repairing the thermocouple is impossible. The product may simply burn out and there is nothing to repair; all that remains is to replace it, as quickly as possible, since a gas boiler will not work without a thermocouple. But there should not be any special problems here, the device can be easily removed and disconnected, and its price is not at all high.

Advice. Sometimes a thermocouple stops working only because there is a weak contact at the connection point. You need to loosen and unscrew the clamping nut, remove the conductor from the gas valve and very carefully clean its end, and then put everything back together.

conclusions

If you decide to heat your home using a gas boiler, remember that a thermocouple is a key element in the safe operation of the unit. The thermocouple device is quite simple and understandable. The price is more than reasonable, and the connection connectors are standard. Therefore, if you need to replace the temperature sensor in case of breakdown, there will be no problems. The only thing to consider is the type and technical characteristics of the device.

Despite the fact that the design of the thermoelectric element is very simple, it is one of the most important parts of modern gas equipment. Acting as a temperature sensor, providing gas control and the presence of a flame, a thermocouple is an ideal element to protect your safety in a house heated with a gas boiler. In any emergency situation, the temperature sensor and shut-off valve will operate in such a way that the gas supply will stop.

A thermocouple is a thermoelectric sensor installed in gas boilers and water heaters equipped with an automatic system independent of the network. This element monitors the presence of a burner flame. It continuously supplies voltage to the control unit solenoid valve. The article discusses what a thermocouple for a gas boiler is, the principle of operation and how to change it if necessary.

Read in the article

How to check the serviceability of a thermocouple in a boiler

Determining a thermocouple malfunction is quite simple. The bypass valve has a clamping rod that regulates the flow of gas. When the boiler is ignited, the solenoid valve opens manually. It is pressed, gas is supplied to the burner, which is ignited using a piezoelectric element or manually. After 10-30 seconds, the mechanical valve is released. At this moment, the rod is blocked by the generated static electricity. Gas continues to flow.

We recommend: Heating design: system design for a private two-story house and cottage, how to design it in an apartment

Replacement of the thermocouple is required if the mechanical clamping time of the valve exceeds the permissible limit. To trigger the temperature sensor, it takes 10-30 seconds of intense heating of the metals. Exceeding this limit indicates the need to replace the sensor.

Changing a thermocouple in a boiler is not difficult. The boiler design provides a special technological hole for installation. The technical characteristics of the sensor are indicated on the information label affixed to the boiler control unit.

You can correctly install the thermocouple in the boiler yourself. At the same time, it should be noted that according to existing requirements, all repair work must be carried out by licensed specialists, representatives of the Gas Service.

It will not be possible to use a faulty thermocouple. During operation, the electromechanical gas inlet valve will not operate.

Thermocouple check

Sometimes it happens that a gas boiler stops working stably and there can be many reasons for this, but often the most common is a malfunction of the thermocouple. The first sign of a gas boiler malfunction is most often a problem with the button on the magnetic box, or rather, it does not lock while the boiler is operating.

In most cases, owners of gas boilers in such a situation simply fix the button in the pressed position using adhesive tape or insulating tape. But, firstly, this solves the problem only temporarily, and secondly, this method can lead to unpredictable consequences, for example, complete failure of the gas boiler or an accident.

If such a problem with the button begins to appear, you should immediately take measures to eliminate it. First of all, you need to check the thermostat. There is a simple method to check a thermocouple with a multimeter:

  1. First, you need to disconnect the gas boiler from the electrical network and gas pipeline to ensure safety during repair work.
  2. At one end of the thermocouple there is a temperature sensor, and at the other end the thermocouple is attached to the solenoid valve using a nut.
  3. The nut is unscrewed from the valve, and the thermocouple is removed from the gas boiler.
  4. Next, you need to heat the thermoelectric converter sensor over a source of stable fire (for example, a gas burner on a stove or a candle). The sensor must be kept at a height of approximately 1 cm from the flame.

    Attention! When the sensor heats up, the body of the thermoelectric converter can heat up to the middle. When heating the thermocouple, you should use gloves to protect your hands from burns.

  5. After the thermocouple has heated up, it is necessary to use a voltmeter or tester set to mV. One probe is applied to the thermocouple body, and the second probe is applied to the output contact.
  6. Within 45-60 seconds after the thermocouple starts heating, the multimeter will begin to record electrical voltage. If the readings fluctuate between 18-25 mV, this will mean that the thermostat is working properly and the problem is most likely poor contact between the solenoid valve and the thermocouple.

Also, in cases where the voltage of the thermoelectric converter does not exceed 18 mV, it may still be operational. It is necessary to move the thermostat in the flame and measure it with multimeter probes again.

The optimal electrical voltage value for stable operation of the solenoid valve is 20-25 mV. But even at 18 mV the valve can continue to operate without knocking out. The button will constantly turn off when the voltage value is less than 16-17 mV.

The most common type of thermocouple failure is burnout of the temperature sensor.

If, upon visual inspection, a deep black dent or hole (burnout) is visible on the surface of the sensor, then the thermoelectric converter must be replaced. Burnout of thermoelectric converters occurs in gas boilers of any manufacturer, which is normal practice in their operation.

Also, to increase the voltage in the thermocouple, and, consequently, increase the sensitivity of the solenoid valve, the igniter hole was specially further enlarged. This leads to an increase in voltage to 30 mV, but the service life of thermostats in such conditions is reduced.

The best known manufacturers and models: characteristics and prices

Denzel GT-950i

One of the best inverter gasoline generators for a gas boiler with a power of 0.9 kW and economical fuel consumption of 0.5 l/hour. Designed for continuous operation for 4.5 hours, it has compact dimensions, a more stable and quiet 4-stroke internal combustion engine, a body in the form of a soundproof casing, which makes its operation quite quiet.

According to reviews from the owners, the mobility of the generator allows it to be used not only to power the boiler, but also other equipment in the house, and to take the generator to the garage or fishing at any time.

Daewoo Power Products GDA 1500I

An excellent, more powerful 1.4 kW inverter synchronous gas generator, which is enough to provide electricity to the most complex heating systems. The four-stroke engine is housed in a soundproof casing, making its operation virtually silent. However, the model has higher fuel consumption - 1.25 l/h, which is still compensated by the presence of an inverter and the ability to adjust the speed. With a sufficiently high power, it has only one outlet.

Through practice, the generator has proven itself to be optimal in performance, reliable and durable.

Cost : 17,000 rub.

Huter DY5000L

Powerful 4.5 kW dual-fuel (gas/petrol) synchronous generator. Designed to power not only the boiler, but also the full-fledged electrical network of an average country house. Designed for continuous operation for 9-9.5 hours, the generator automatically turns off when overheated, overloaded or low oil level. No obvious shortcomings were observed due to the practice of use.

CHAMPION IGG980

An excellent inverter gasoline generator with a power of 1.1 kW and economical fuel consumption of 0.6 l/h. It is distinguished by an extremely affordable price, small size, greater power than stated by the manufacturer, and the ability to adjust it. But, like other inexpensive models, it has characteristic disadvantages in the form of a low-quality sinusoid at the output, noisy operation, poor assembly, which causes oil and gasoline leaks.

Possible malfunctions and methods for eliminating them

If, when you press the gas supply button, the burner turns on and immediately goes out, this indicates a malfunction of the thermocouple. It may also be the result of poor contact between the converter and the solenoid valve.

Repairing a gas boiler thermocouple malfunction is as follows:

  • remove the end of the thermocouple by unscrewing the clamping nut with a wrench, with which the transducer is attached to the valve;
  • if upon inspection the presence of contaminants or oxides is detected, clean the contact area with fine sandpaper;
  • Next, use a multimeter to check the functionality of the device.

If, when checking, the sensor shows a voltage of 50 mV, you can try to start the boiler. If the problem persists and the burner goes out, this may indicate a faulty solenoid valve.

If the valve is in working condition, it is necessary to ensure the correct connection of the converter to the valve: find the appropriate position of the clamping nut for optimal contact.

You should know that if the gas boiler converter fails, the device cannot be restored. Here it is necessary to replace the thermocouple by installing a new sample in its place. Products in this category are offered by many domestic and foreign manufacturers, including Arbat, Zhukovsky AOGV plant, Honeywell concern and other industrial companies. The price range for this device varies between 600-2000 rubles.

The main areas of application of thermocouples are automation of gas equipment, foundry industry installations and many other areas of production. Based on this device, a whole range of thermostats and thermometers for household and industrial use has been developed. In the hands of folk craftsmen, a thermoelectric converter can become the basis for a mini power station; it is used to create chargers with which you can charge low-power devices from an open fire, including from a fire.

Reviews

Vlad, Chelyabinsk: “The old boiler, manufactured in 2003, has recently started acting up - sometimes it starts, sometimes it doesn’t. I went to the forums to find out what was wrong, and it turned out that the thermocouple had failed. I went to the nearest store that sells spare parts for gas equipment and bought a thermocouple there, which is installed exactly on such old models. I decided not to try it with my own hands - I called specialists. The master additionally cleaned the elements on the boiler from dirt and rust, for which a special thank you.”

Igor, Kovel: “Thermoelements were developed back in the 1950s, specifically for Soviet gas boilers. If you know how they are designed and on what principle they work, there should be no problems. If necessary, the part can be repaired. And if it completely breaks down, it’s not a problem to find a new one. The technical transparency of the system is important to me, so I choose it rather than modern Chinese automation with a bunch of chips.”

The thermoelectric element, despite the simplicity of its design, is considered one of the most important parts of a gas boiler. It “scans” the temperature and checks the presence of a flame in the burner, being responsible for the safe operation of the equipment. Therefore, if a thermoelement fails, it must be replaced with a new one or, if possible, repaired.

Thermoelectric sensors - thermocouples - are used exclusively in gas boilers and hot water columns equipped with non-volatile safety automatics. The element's task is to monitor the presence of a burner flame by continuously applying voltage to the solenoid valve of the SIT 630 control unit (or similar). Our goal is to tell you what a thermocouple is, how it works and changes in the event of a malfunction.

How and in what cases can it be restored?

The thermocouple is designed in such a way that any damage or contamination can reduce the voltage it produces below a critical level. A very common cause of malfunction is carbon deposits or a layer of soot on its working (heated) part. To restore the thermocouple, just clean it with a soft brush or cotton wool and alcohol, while avoiding scratches and other damage. After cleaning, it is worth checking the voltage again following the instructions above.

We recommend: Penoplex - technical characteristics, dimensions, prices and installation features

Oxidized contacts are also a common cause; they can be carefully treated with sandpaper. If the thermocouple has a deep black dent or hole due to burning, it is guaranteed to need to be replaced.

What metals are thermocouple conductors made of?

All thermocouples are created from certain alloys of noble and base metals that have a constant, repeatable relationship between temperature difference and voltage.

Each group of alloys is used for specific temperature ranges and is used in installed heating appliances.

There are three main types of thermocouples most commonly used in boiler markets:

  1. Type E. Made from chromel and constant plates. It is highly reliable. Has the factory marking THKn. The operating temperature range is from 0 to +600°C.
  2. Type J. Similar to the previous thermocouple, but iron is used instead of chromel. The device is practically not inferior in functions to type E, but the price is much lower. Labeling: TFA. The temperature range varies from -100 to +1200°C.
  3. Type K. The most common and widely used type of thermocouple. Marking: THA. The composition contains plates made of chromel and aluminum. Operating temperatures range from – 200 to +1350°C. Such devices are quite sensitive to the slightest temperature changes, but at the same time they are highly dependent on the environment. For example, carbon dioxide can significantly reduce the life of a device and cause premature repairs.

Why does a gas stove need a thermocouple?

The gas in the stove burner is ignited with matches, a manual piezo lighter or a built-in electric ignition. Then the flame should burn on its own without human intervention until the fuel is turned off by the valve.

However, often the fire on a gas hob or oven goes out as a result of a gust of wind or a splash of water from a boiling pan. And then, if there is no one nearby in the kitchen, methane (or propane) begins to flow into the room. As a result, when a certain concentration of gas is reached, a bang occurs with fire and destruction.


The thermocouple monitors the presence of an open flame in the burner, and if there is none, it shuts off the gas supply within half a minute to a minute to prevent a tragedy

The working function of a thermocouple is to control the presence of a flame. While the gas is burning, the temperature at the tip of the control device reaches 800–1000 0C, and often higher. As a result, an EMF arises, which keeps the gas solenoid valve on the nozzle to the burner open. The burner is working.

However, when the open flame disappears, the thermocouple stops producing EMF to the electromagnet. The valve and fuel supply are shut off. As a result, the gas does not enter the kitchen without accumulating in it, which eliminates the possibility of a fire from such an emergency situation.

A thermocouple is a simple temperature sensor without any electronic devices inside. There is nothing to break in it. It can only burn out from prolonged use.

The following article, which is entirely devoted to this interesting issue, will introduce you to a complete set of sensors designed to control and safety the operation of a gas water heater.


Thermocouple burnout usually occurs only in gas boilers and boilers that operate continuously. In gas stoves, the gas control temperature sensors in question last 20–30 years before replacement.

Among the advantages of thermocouples:

  • simplicity of the device and the absence of breaking mechanical or burned out electrical elements;
  • the device is cheap - about 800–1500 rubles, depending on the model of the gas stove;
  • long service life;
  • high efficiency of flame temperature control;
  • quick gas shut-off;
  • ease of replacement, which you can do yourself.

The thermocouple has only one significant drawback - the difficulty of repairing the device. If the thermocouple sensor is faulty, it is easier to replace it with a new one.

To repair such a device, it is necessary to weld or solder two different metals at high temperature (about 1,300 0C). It is extremely difficult to achieve such conditions in everyday life at home. It is much easier to buy a new control unit for a gas stove as a replacement.

Item Description

The thermocouple is practically the only device that measures extremely high temperatures. It is installed in various boiler equipment. The element’s task is to control the thermal regime, protecting the system from possible overheating.

If there is no flame in the combustion chamber for any reason, the thermocouple automatically shuts off the gas supply. That is, it is a protective element.

In general, a device that measures the temperature of the working environment is widely in demand in various areas of human activity: industry, medicine and other areas where accurate temperature is important.

Design and principle of operation

The operation of a thermocouple is based on the thermoelectric Seebeck effect. According to it, at the ends of conductors connected in series from different metals, provided that their contacts are at different temperatures, thermo-emf (TEMF) occurs.

That is, it is necessary to have two conductors of different compositions that can withstand intense heat, and high-temperature heat (in this case from combustible natural gas) at the point of their connection.

In most pairs, the electromotive force that arises between the cold and hot contacts is very small and of little use. But there are metals and alloys, the combination of which gives up to 4–5 mV/100 0C. And this is already quite enough to control the electromagnet that controls this or that shutter.


The thermo-EMF in most types of thermocouples for gas stoves reaches 15–30 mV, and 5–10 mV is usually enough to keep the solenoid valve open

The operating principle of thermocouples built into gas stoves is extremely simple:

  1. There is a flame - TEMF appears between the contacts, the valve for the gas supply to the burner is open.
  2. There is no fire - the thermoelectric force disappears, the valve closes under spring pressure and shuts off the gas.

A thermocouple consists of two thermostable conductors up to one and a half meters long, which are connected at one end by soldering or welding.

It is this tip that is directly in the fire and is heated by the burning gas. The second end of the device is a pair of contacts or a connector for connecting to a solenoid valve.

Specifications

According to GOST P 8.585-2001, a thermocouple is a temperature-monitoring device consisting of 2 conductors made of different alloys. Each alloy has a different resistance and electrical potential. Contact between conductors occurs at one or several points, and in some models it is possible due to the presence of a compensation wire. Base metals are used to make thermocouples.

The thermocouple looks very simple and consists of a cast head housing, equipped with a cover and phosphor pads, thanks to which the linear expansion of the electrodes is compensated. The tip of the product serves to reliably isolate the working junction, and the protective tube consists of a working and non-working section. All connecting wires are routed through a fitting with an asbestos seal. If the electrodes are made of noble metals, products made of phosphorus or quartz can be used as protective tubes.

The error in instrument readings is one degree , which is considered a fairly significant indicator in the operation of gas heating equipment, and does not allow the devices to be considered high-precision instruments. The inaccuracy of temperature measurements is explained by the design features of the thermocouple. The fact is that the connection of conductor plates to each other occurs in different ways. In some models, the connection is made using spot welding, in others - by soldering or crimping.

If the junction of two conductors is made poorly, the error will be one or more degrees. This is a critical error value, an increase in which can negatively affect the operation and safety of the boiler. Therefore, when choosing a thermocouple, it is necessary to focus on products from well-known and trusted manufacturers, since for AOGV an error of one degree is an unaffordable luxury.

Types of temperature sensors for gas

Thermocouples of gas stoves differ in the alloy of conductors and the type of connection to the valve. And the main thing here is that each manufacturer of gas-powered equipment uses its own versions of electromagnets with different connection connectors.

We recommend: Which boiler is more profitable - gas or electric?

In most cases, it is impossible to move the thermocouple gas control sensor from one tile to another.


The thermocouple must correspond to the model of the gas stove; installing a “left” control device is prohibited for safety reasons

The following alloys and metals are used to create thermocouples:

  • constantan + chromel;
  • copper + constantan;
  • copper+copel;
  • nisil + nichrosil;
  • alumel+chromel;
  • constantan+iron;
  • chromel+copel;
  • platinum+platinum;
  • tungsten+rhenium.

The accuracy of the device and its operating temperature range depend on the alloys used. For example, a chromel-alumel thermocouple is designed to operate at 0–1100 0C, an iron-constant thermocouple at 0–700 0C, and a platinum-platinum-rhodium thermocouple can withstand heating up to +1700 0C.

Household gas stoves usually use thermocouple sensors made of alumel and chromel or constantan and iron. They are inexpensive and quite suitable for the temperature conditions of a gas cooktop.

Prices: summary table

ModelType of fuelpower, kWtFuel consumption, l/hOperating time, hCost, rub.
Denzel GT-950ipetrol0,90,54,519 800
Daewoo Power Products GDA 1500Ipetrol1,41,25417 000
Huter DY5000Lpetrol/gas4,52,3934 000
CHAMPION IGG980petrol1,10,649 800

Gas control repair manual

If the gas on the stove goes out, then the problem may lie not only in the thermocouple. However, most often this is precisely the problem.

The main sign of problems with gas control is that after igniting the burner and releasing the handle or button to open the “blue fuel”, the flame immediately goes out. This occurs due to the valve closing, since the thermo-EMF to keep it open is absent or insufficient.

The reasons for the noise of gas stove burners are described in detail in the article, the useful information of which is worth reading.


Before purchasing a new thermocouple, you need to determine the reason for the poor operation of the existing device - perhaps the problem is loose contacts on the valve, then you just need to tighten them

You should independently check, repair and replace the thermocouple in a gas stove with your own hands only when the gas is completely shut off. First you need to close the valve on the cylinder with the gas mixture or the methane pipe, and only then begin any work. Also, do not forget about turning off the power supply if the design contains volatile devices.

The thermocouple tip is located directly next to the burner and gas fire. And in the oven you can find it near the flame divider in the upper part of the oven. This tip should be free of carbon deposits, mineral deposits and any damage.

If the working tip of the thermocouple sensor is covered with scale, it must be cleaned off with sandpaper. The more carbon deposits, the less heat reaches the thermocouple, and the less it accordingly creates an EMF. The resulting millivolts may simply not be enough to open the solenoid valve.

How to check before replacing?

The thermocouple usually has one tip for installation near the fire. But there are also options with two or three temperature control tips. They are usually used in ovens, but it all depends on the specific model of the stove.

Thermocouples with several working tips have a peculiarity - if only one of them is not heated or fails, the solenoid valve will be closed. Therefore, in order to accurately find the cause of the problems, such thermocouple devices will have to be checked especially carefully. Only one of the sensors may be faulty.


A working thermocouple for a gas stove, when heated over a candle, produces an EMF of the order of 15–20 mV after 20–30 seconds - if less, then the sensor must be changed

Another point is that the thermocouple conductors in the area up to the valve must be tensioned or dangling in the body of the plate. At the same time, their connection to the electromagnet must be rigid; a connector hanging “on my word of honor” is unacceptable here.

The devices in question are produced with lengths from 40 to 130 cm. You should choose a thermocouple gas monitoring device based on this indicator very carefully. On the one hand, the conductor wire should not be over-tensioned, and on the other hand, it should not lie on heated surfaces or dangle freely.

How to change the device?

Before replacing a damaged thermocouple in a gas stove, you should inspect the device for:

  • the presence of carbon deposits on the working tip (if there is any, it must be cleaned off with sandpaper);
  • no burnout of this tip (in this case, only complete replacement);
  • the rigidity of the connection between the contacts of the thermocouple sensor and the valve (if necessary, tighten);
  • serviceability of the thermocouple itself with the output of an EMF at a level of at least 15 mV when heating.

The device in question should only be replaced when it is definitely faulty. In many cases, to get a gas stove to work again, you can get by by cleaning the tip from carbon deposits and checking the contacts.


To replace the thermocouple, you will have to remove the front panel from the gas stove, and also lift the top cover with the burners on it

The working tip of the thermocouple is rigidly fixed near the burner or burner using a nut. If it cannot be unscrewed due to scale, then you should not put too much pressure on the key. This can only break the fastening. It is better to use a solvent first.

The second end of the thermocouple is attached to the solenoid valve using a threaded connector or two crimp contacts. Removing them doesn't seem difficult. The new thermocouple sensor is installed in a similar sequence - one end of it is attached near the burner, and the other to the electromagnet.

Thermal generator for gas water heater

Buy a spare part for the Protherm boiler Bear 0020027521

Multiple thermocouple 820mV. Article - 0020027521. Original. this is not analogue.

Used on Protherm Medved boilers 20, 30, 40, 50 TLO

Serves to generate Thermo EMF. When heated, it generates a small current and keeps the gas valve of the burner open.

Multiple thermocouple, Thermal generator, Multiple thermocouple Proterm boiler

If you suddenly don’t know exactly whether this thermocouple will fit your boiler, then the best thing to do is call us and ask. Our professionals will accurately select you a spare part specifically for your boiler.

This item is not considered a custom item and is always in STOCK. You can pick up your spare part Thermocouple multiple 820mV Protherm (article Protherm-0020027521) from the warehouse (see Contacts)

Delivery of thermocouples in Moscow and the Moscow region is carried out by our couriers throughout the day to your address.

This thermocouple is installed on the Proterm Medved boiler and also on other boilers where the SIT gas valve is used / it is mounted in a wick group and connected to the gas valve with 2 wires. It is especially important to correctly configure the thermogenerator using a multimeter. . If you suddenly don’t know how to do this, it’s better to call our master.

Buy Spare part 0020027521 Multiple thermocouple 820mV For Protherm gas water heaters.

If you suddenly do not know the number of the spare part you need, call us by phone or write a letter in the “Feedback” section. We strongly do not suggest that you choose the number of the spare part you need on your own. Call our specialists.

How to Buy Without any problems - click the Buy or Buy without registration button and place your order through the shopping cart. We will contact you

Payment Cash at the warehouse Payment by account Payment to Sber Bank card

Delivery 0020027521 Multiple thermocouple 820 mV in Moscow and the region to your address. Pickup from our warehouse from 9 to 18.

0020027521 Purchase multiple thermocouple 820mV.

Rating
( 1 rating, average 5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]